Metraipolis › archive › dc_096b9ef66f87

Joint Supervised and Self-Supervised Training with Acquisition-Robust Techniques for Accelerated 4D Flow MRI Reconstruction — arXiv:2609.38644

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.38644
License (as archived)
CC0-1.0
Archived
2026-10-07T14:46:49.112Z
SHA-256 of the archived text
734d2e681686f65ab370e58987e0387f9355cc910af93a17dc744fa3647bd63b
Stable URL of this page
https://metraipolis.com/documento/dc_096b9ef66f87

How to cite

Joint Supervised and Self-Supervised Training with Acquisition-Robust Techniques for Accelerated 4D Flow MRI Reconstruction — arXiv:2609.38644 — arXiv (en), https://arxiv.org/abs/2609.38644 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_096b9ef66f87 (Metraipolis archive dc_096b9ef66f87, sha256 734d2e681686f65ab370e58987e0387f9355cc910af93a17dc744fa3647bd63b)
BibTeX
@misc{dc096b9ef66f87,
  title = {Joint Supervised and Self-Supervised Training with Acquisition-Robust Techniques for Accelerated 4D Flow MRI Reconstruction — arXiv:2609.38644},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.38644},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_096b9ef66f87; sha256 734d2e681686f65ab370e58987e0387f9355cc910af93a17dc744fa3647bd63b},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.38644. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

4D flow MRI measures time-resolved, three-directional blood velocity but requires long acquisition times, and its diagnostic signal is carried by the phase difference \emph{between} velocity encodings, not by image magnitude. Recent work has developed a per-encoding variational network to address image reconstruction in this field. In this work, we incorporate a joint supervised and self-supervised training regime and utilize both magnitude and velocity data during supervision. At the same time, we add multiple acquisition-robust and conditioning strategies based on the acceleration factors. On the CMRx4DFlow~2026 aortic dataset (1.5 and 3T), our model lowers RelErr by $38$--$50\%$ and AngErr by $7.0$--$8.7^\circ$ against a training-matched baseline across $R{=}10$--$50$, improving on every held-out subject at every acceleration. Our model also shows strong generalization ability to transfer on out-of-distribution data by employing the joint training scheme, with an increase of $7.2\%$ in SSIM and decrease of $38\%$ and $31\%$ in AngErr and RelErr respectively.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-10-01 in cs.CV).
Categorie arXiv: Image and Video Processing (eess.IV) ; Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2609.38644 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-07T14:19:00.897Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-10-01?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).