Metraipolis › archive › dc_08f77ddf30c5
Feature Scaling Beats Architecture Choice in Offline Respiratory Screening for Low-Resource Clinics — arXiv:2610.33030
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.33030
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-27T07:59:26.771Z
- SHA-256 of the archived text
2e7364fbae93860b8c07f0e24515c503d544228fa12d9e276f4741e6be45dd6a- Stable URL of this page
https://metraipolis.com/documento/dc_08f77ddf30c5
How to cite
Feature Scaling Beats Architecture Choice in Offline Respiratory Screening for Low-Resource Clinics — arXiv:2610.33030 — arXiv (en), https://arxiv.org/abs/2610.33030 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_08f77ddf30c5 (Metraipolis archive dc_08f77ddf30c5, sha256 2e7364fbae93860b8c07f0e24515c503d544228fa12d9e276f4741e6be45dd6a)
BibTeX
@misc{dc08f77ddf30c5,
title = {Feature Scaling Beats Architecture Choice in Offline Respiratory Screening for Low-Resource Clinics — arXiv:2610.33030},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.33030},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_08f77ddf30c5; sha256 2e7364fbae93860b8c07f0e24515c503d544228fa12d9e276f4741e6be45dd6a},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.33030. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Deep models are the usual choice for respiratory sound classification, but in clinics without GPUs or connectivity that choice carries a cost. We compare classical and deep classifiers on a five-class respiratory-sound corpus of 1,211 clips (asthma, COPD, pneumonia, Bronchial, healthy) from 201 patient groups, with a 3.86:1 class imbalance, using pre-registered patient-grouped cross-validation (25 runs per configuration). An SVM over 30 summary features (MFCC, ZCR and RMS statistics) reaches macro recall 0.78 and 0.71 recall on the rarest class. A 1.13M-parameter convolutional recurrent network over log-Mel spectrograms reaches 0.75 to 0.77, and no difference between model families is resolved. The largest single effect we measure is a preprocessing effect rather than an architectural one. Standardizing the SVM's features, a routine step for RBF kernels, moves its macro recall from 0.51 to 0.78, a 27-point swing wider than any gap between model families here. Augmentation did not help: SMOTE, waveform augmentation and SpecAugment have no measurable effect. Latency does not separate the models (51 to 74 ms per clip on a CPU-only laptop), but the classical models avoid a 449 MB PyTorch runtime. Clip-level splits, which let a patient's recordings fall on both sides, inflate macro recall by 7.5 to 9.8 points. Recording source is strongly tied to label (Cramer's V = 0.65 between native sampling rate and class), and in an exploratory analysis clips recorded at a class's minority rate are mostly assigned to classes typical of that rate; we state this confound as the paper's main limitation. Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.AI, nuovi lavori del giorno). Categorie arXiv: Machine Learning (cs.LG) ; Artificial Intelligence (cs.AI); Sound (cs.SD). Pagina del lavoro: https://arxiv.org/abs/2610.33030 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-27T07:55:30.792Z dalla pagina https://arxiv.org/list/cs.AI/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).