Metraipolis › archive › dc_085d5e6533cd
Radio Frequency Detection and Classification of Microplastics in Water — arXiv:2609.20507
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.20507
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-10T04:09:06.552Z
- SHA-256 of the archived text
334badb3859634e164224f122329f462d912f94f0d51563b89186e5145b4d235- Stable URL of this page
https://metraipolis.com/documento/dc_085d5e6533cd
How to cite
Radio Frequency Detection and Classification of Microplastics in Water — arXiv:2609.20507 — arXiv (en), https://arxiv.org/abs/2609.20507 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_085d5e6533cd (Metraipolis archive dc_085d5e6533cd, sha256 334badb3859634e164224f122329f462d912f94f0d51563b89186e5145b4d235)
BibTeX
@misc{dc085d5e6533cd,
title = {Radio Frequency Detection and Classification of Microplastics in Water — arXiv:2609.20507},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.20507},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_085d5e6533cd; sha256 334badb3859634e164224f122329f462d912f94f0d51563b89186e5145b4d235},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.20507. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Micro- and nano-plastic particles (MPs/NPs) are ubiquitous environmental contaminants whose increasing abundance and potential health impacts have created an urgent need for rapid, label-free detection methods. As particle size decreases to the low-micrometer range, conventional optical and spectroscopic techniques become increasingly challenging because of limited throughput and/or complex sample preparation. In this work, we present a machine learning (ML)-assisted radio-frequency (RF) dielectric spectroscopic cytometry (DiSC) platform for the label-free detection and classification of MPs. Eight types of $ 10 $ {\mu}m nominal-diameter MP particles suspended in deionized (DI) water were characterized at four frequencies spanning $ 0.2\text{-}9\text{ GHz} $. The measured alterations in RF scattering parameters (S-parameters), referenced to the carrier medium, were used to train supervised ML models for material classification, including the identification of MPs in mixed samples and saline-water environments. For eight MP classes suspended in DI water, the proposed method achieved macro-average F1-score, precision, and recall values exceeding $ 0.71 $. Furthermore, PET classification performance was largely maintained in saline carrier media containing $3.3\% $ and $ 6.6\% $ sea salt. These results demonstrate the feasibility of ML-assisted RF DiSC for rapid, single-particle MP classification in aqueous environments. Future work will focus on improving classification performance through enhanced RF calibration, increased spectral coverage, larger training datasets, and validation using environmentally aged and biologically contaminated microplastics.
Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-18 in cs.LG).
Categorie arXiv: Machine Learning (cs.LG).
Pagina del lavoro: https://arxiv.org/abs/2609.20507 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-10T03:48:18.369Z dalla pagina https://arxiv.org/catchup/cs.LG/2026-09-18?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).