Metraipolis › archive › dc_0745e827c4ec
When can multi-fragment 2D/3D registration be trusted? Calibrated certification and uncertainty-driven view planning for pelvic fracture fluoroscopy — arXiv:2611.05618
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2611.05618
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-05T18:30:17.078Z
- SHA-256 of the archived text
547001bfd5df4d59e5251fc2d0980bb8ea5e44f8fa9d245d8d7fcb38dd63da3f- Stable URL of this page
https://metraipolis.com/documento/dc_0745e827c4ec
How to cite
When can multi-fragment 2D/3D registration be trusted? Calibrated certification and uncertainty-driven view planning for pelvic fracture fluoroscopy — arXiv:2611.05618 — arXiv (en), https://arxiv.org/abs/2611.05618 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_0745e827c4ec (Metraipolis archive dc_0745e827c4ec, sha256 547001bfd5df4d59e5251fc2d0980bb8ea5e44f8fa9d245d8d7fcb38dd63da3f)
BibTeX
@misc{dc0745e827c4ec,
title = {When can multi-fragment 2D/3D registration be trusted? Calibrated certification and uncertainty-driven view planning for pelvic fracture fluoroscopy — arXiv:2611.05618},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2611.05618},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_0745e827c4ec; sha256 547001bfd5df4d59e5251fc2d0980bb8ea5e44f8fa9d245d8d7fcb38dd63da3f},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.05618. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Registering a segmented CT to fluoroscopy can locate every fracture fragment but can guide surgery only when trusted. After each shot, our closed loop registers all fragments, bounds their errors with a calibrated sandwich covariance, flags implausible or ambiguous ones, and stops or plans the next view. On simulated fluoroscopy of 60 held-out fracture CTs with realistic image uncertainty, 95% bounds covered 83% of unflagged fragments and 91% of those within 5mm, but from the second view on 14% failed by over 5mm, a third with bounds of at most 2mm. A fragment's shift when a view was added separated tightly bounded failures best (exploratory; AUC 0.94, bound 0.81). Requiring that the newest view moved no fragment beyond its bound, preferred post hoc, lowered false stops at 2mm from 23% to 6% overall, with 345 instead of 362 correct ones but more trajectories uncertified; delaying the stop did not, and other signals at equal acceptance left 10-15% false. With a segmentation error shared by all views (median Dice 0.89), 21% of this rule's stops were false against 10% without it (15 cases; exploratory). Minimax planning certified sooner than the clinical protocol without the check (4.20 versus 4.72 shots, Holm p <0.001), but no criterion reached the pre-specified endpoint, a true 2mm error, significantly sooner, even in the true basin. On real fluoroscopy of five intact pelves no 2mm certificate was false. Trust takes evidence across views, not only a calibrated local bound. Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.CV, nuovi lavori del giorno). Categorie arXiv: Image and Video Processing (eess.IV) ; Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2611.05618 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-05T18:19:49.069Z dalla pagina https://arxiv.org/list/cs.CV/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).