Metraipolis › archive › dc_06cd4727e72e
CompliantWBC: Whole-Body Compliance for Heavy Humanoids via Force Latent Estimation and Residual Impedance Targets — arXiv:2609.33310
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.33310
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-08T00:17:07.364Z
- SHA-256 of the archived text
eec15c2b8531bb3bfcdd9cc6e04a30b5258c9eb67f545cbc3db089a44ab29a12- Stable URL of this page
https://metraipolis.com/documento/dc_06cd4727e72e
How to cite
CompliantWBC: Whole-Body Compliance for Heavy Humanoids via Force Latent Estimation and Residual Impedance Targets — arXiv:2609.33310 — arXiv (en), https://arxiv.org/abs/2609.33310 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_06cd4727e72e (Metraipolis archive dc_06cd4727e72e, sha256 eec15c2b8531bb3bfcdd9cc6e04a30b5258c9eb67f545cbc3db089a44ab29a12)
BibTeX
@misc{dc06cd4727e72e,
title = {CompliantWBC: Whole-Body Compliance for Heavy Humanoids via Force Latent Estimation and Residual Impedance Targets — arXiv:2609.33310},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.33310},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_06cd4727e72e; sha256 eec15c2b8531bb3bfcdd9cc6e04a30b5258c9eb67f545cbc3db089a44ab29a12},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.33310. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Whole-body compliant control is essential for deploying heavy humanoids under high payload in human-centric environments. Most prior force-aware learning-based pipelines focus on end-effector resistance, per-link upper-body springs, or end-effector stiffness modulation, leaving arbitrary-site perturbations on heavy platforms with lower-body engagement largely unaddressed. We close this gap with CompliantWBC comprising: (1) A base policy trained with RL to maximize compliance-fidelity reward, guided by a multi-site whole-body impedance reference controller, extending classical Cartesian impedance to any controlled link; (2) A bounded residual policy that edits the per-link impedance equilibrium over a frozen base, correcting the coarse but structured wrench estimate supplied by a force encoder co-trained behind a gradient barrier; (3) A Phong-weighted force-origin sampler with an axis-decoupled pelvis anchor induces lower-body-inclusive compliance curriculum training via two interpretable parameters. We evaluate CompliantWBC in simulation against both compliant and stiff baselines, achieving best compliant fidelity of 2.58cm deviation from analytical solutions, and demonstrate it on a real heavy humanoid across static/dynamic force reaction, board wiping, squat under payload, and cooperative payload transport. Project website: this https URL Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-29 in cs.RO). Categorie arXiv: Robotics (cs.RO). Pagina del lavoro: https://arxiv.org/abs/2609.33310 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-07T23:52:16.468Z dalla pagina https://arxiv.org/catchup/cs.RO/2026-09-29?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).