Metraipolis › archive › dc_06505829280a
Numerical Simulation of Electrical Properties in Cortical and Trabecular Bone: A Simplified Model — arXiv:2609.31584
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.31584
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-08T02:58:09.140Z
- SHA-256 of the archived text
0f56253d2685002a4277ef05f9d645beb0ea7e2445e96802506d6dd3924837dc- Stable URL of this page
https://metraipolis.com/documento/dc_06505829280a
How to cite
Numerical Simulation of Electrical Properties in Cortical and Trabecular Bone: A Simplified Model — arXiv:2609.31584 — arXiv (en), https://arxiv.org/abs/2609.31584 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_06505829280a (Metraipolis archive dc_06505829280a, sha256 0f56253d2685002a4277ef05f9d645beb0ea7e2445e96802506d6dd3924837dc)
BibTeX
@misc{dc06505829280a,
title = {Numerical Simulation of Electrical Properties in Cortical and Trabecular Bone: A Simplified Model — arXiv:2609.31584},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.31584},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_06505829280a; sha256 0f56253d2685002a4277ef05f9d645beb0ea7e2445e96802506d6dd3924837dc},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.31584. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
The electrical properties of biological tissues depend on their composition and microstructure and determine their response to applied electric fields. In bone tissue, these properties are closely related to its composition, porosity, and microstructural organization. However, simplified models that link bone microstructure (trabecular and cortical) to its effective electrical properties while accounting for the electrical anisotropy of cortical bone remain scarce. In this work, a multiscale approach was developed, combining finite element simulations with Bruggeman-based homogenization models. Trabecular bone was modeled using microCT derived geometries, and its effective conductivity was analyzed as a function of BV/TV and free water content. Cortical bone was represented by a simplified three-dimensional network of Haversian canals (axial = z) and Volkmann canals (transverse), incorporating their directional organization through an anisotropic Bruggeman formulation. The models captured the conductivity range reported experimentally for trabecular bone (approximately 25-200 mS/m) and reproduced the anisotropic behavior observed in the cortical FEM simulations, with higher conductivity in the axial direction. In the generated cortical geometries, 65.5% of the total porosity was associated with axial Haversian canals. At the macroscale, the tibia model with lower trabecular and cortical BV/TV and reduced cortical thickness showed an approximately 38-39% reduction in impedance relative to the reference model. These results indicate that microstructural variations in bone tissue are reflected in its effective electrical properties and in the macroscopic impedance of the model, providing a physical and computational basis for future investigations into the sensitivity of electrical measurements to changes in bone microstructure. Tema degli esploratori: matematica e informatica teorica (retro-catalogo arXiv: annunci del 2026-09-28 in math.NA). Categorie arXiv: Medical Physics (physics.med-ph) ; Numerical Analysis (math.NA). Pagina del lavoro: https://arxiv.org/abs/2609.31584 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-08T02:27:28.575Z dalla pagina https://arxiv.org/catchup/math.NA/2026-09-28?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).