Metraipolis › archive › dc_062a62bfe53e

Missing Modality-Aware Calibration for Trustworthy Brain Tumor Segmentation — arXiv:2610.11419

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.11419
License (as archived)
CC0-1.0
Archived
2026-10-09T05:57:48.990Z
SHA-256 of the archived text
4f4ef66d0d9110e8cc23f10d0d2495164b3df9733383d0b227347936f03be66d
Stable URL of this page
https://metraipolis.com/documento/dc_062a62bfe53e

How to cite

Missing Modality-Aware Calibration for Trustworthy Brain Tumor Segmentation — arXiv:2610.11419 — arXiv (en), https://arxiv.org/abs/2610.11419 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_062a62bfe53e (Metraipolis archive dc_062a62bfe53e, sha256 4f4ef66d0d9110e8cc23f10d0d2495164b3df9733383d0b227347936f03be66d)
BibTeX
@misc{dc062a62bfe53e,
  title = {Missing Modality-Aware Calibration for Trustworthy Brain Tumor Segmentation — arXiv:2610.11419},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.11419},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_062a62bfe53e; sha256 4f4ef66d0d9110e8cc23f10d0d2495164b3df9733383d0b227347936f03be66d},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.11419. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Multimodal brain tumor segmentation typically leverages multiple MRI modalities, yet incomplete modality acquisition is common in clinical practice due to protocol heterogeneity and scan failures. Although recent methods maintain segmentation accuracy under missing modality conditions, they frequently overlook prediction reliability, leading to miscalibrated confidence estimates that hinder clinical adoption. Existing calibration techniques are largely modality-agnostic or assume that prediction difficulty decreases monotonically as additional modalities become available. However, in brain tumor segmentation, prediction difficulty depends primarily on which modalities are absent rather than how many, leading to combination-specific and spatially heterogeneous calibration errors. To address this, we propose Missing Modality-Aware Local Temperature Scaling (MMA-LTS), a post-hoc voxel-wise confidence calibration method. It estimates a spatially adaptive temperature field conditioned on a modality-availability learnable token and a voxel-wise difficulty score. Experiments on BraTS 2020 and FeTS 2024 show that MMA-LTS improves calibration while preserving the segmentation accuracy of state-of-the-art models across diverse missing-modality scenarios, thereby enhancing trustworthiness toward clinical deployment.

Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.AI, nuovi lavori del giorno).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Artificial Intelligence (cs.AI).
Pagina del lavoro: https://arxiv.org/abs/2610.11419 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-09T05:47:01.688Z dalla pagina https://arxiv.org/list/cs.AI/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).