Metraipolis › archive › dc_061559eccd6d

ErgoAssist: Cognition-Aware Posture Feedback in Wearable Ergonomic Systems — arXiv:2609.00440

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.00440
License (as archived)
CC0-1.0
Archived
2026-10-17T06:51:54.531Z
SHA-256 of the archived text
cf64dca568334c89a44111885568282a9bf800be73c6f76edfeb4b06d93a6b67
Stable URL of this page
https://metraipolis.com/documento/dc_061559eccd6d

How to cite

ErgoAssist: Cognition-Aware Posture Feedback in Wearable Ergonomic Systems — arXiv:2609.00440 — arXiv (en), https://arxiv.org/abs/2609.00440 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_061559eccd6d (Metraipolis archive dc_061559eccd6d, sha256 cf64dca568334c89a44111885568282a9bf800be73c6f76edfeb4b06d93a6b67)
BibTeX
@misc{dc061559eccd6d,
  title = {ErgoAssist: Cognition-Aware Posture Feedback in Wearable Ergonomic Systems — arXiv:2609.00440},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.00440},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_061559eccd6d; sha256 cf64dca568334c89a44111885568282a9bf800be73c6f76edfeb4b06d93a6b67},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.00440. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Prolonged digital device use has made poor posture and musculoskeletal discomfort pervasive among knowl- edge workers. Existing ergonomic wearables rely solely on posture thresholds, frequently interrupting users during high-focus moments and leading to alert fatigue and abandonment. Yet posture and cognitive load are closely coupled, and most systems remain cognitively unaware. We present ErgoAssist, a head-worn ergonomic assistant that detects poor posture using IMU-based head tracking and estimates task-induced cognitive load using a consumer-grade EEG headband for continuous everyday use. In a controlled lab study, ErgoAssist achieves 81% posture classification and 90.2% task induced cognitive load estimation accuracy under leave-one-subject-out evaluation. In a preliminary real-time deployment, cognition-aware alerting reduces alert frequency by 81%, improves perceived usability by 43%, task performance by 25%, and improves posture correction rate by 38%, delivering fewer but better-timed interventions rather than merely suppressing alerts.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-02 in cs.HC).
Categorie arXiv: Human-Computer Interaction (cs.HC).
Pagina del lavoro: https://arxiv.org/abs/2609.00440 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-17T06:41:35.403Z dalla pagina https://arxiv.org/catchup/cs.HC/2026-09-02?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).