Metraipolis › archive › dc_05ae7eda6f14

CFD Correction of Open Tip Clearance Flow in a Compressor Cascade Using VAE Latent Space Adaptation — arXiv:2609.28558

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.28558
License (as archived)
CC0-1.0
Archived
2026-10-08T05:25:38.282Z
SHA-256 of the archived text
91c6e58de5bb4c5d1ceddec497f2248a750dcc8c0bdfdd64d552655711c3ce20
Stable URL of this page
https://metraipolis.com/documento/dc_05ae7eda6f14

How to cite

CFD Correction of Open Tip Clearance Flow in a Compressor Cascade Using VAE Latent Space Adaptation — arXiv:2609.28558 — arXiv (en), https://arxiv.org/abs/2609.28558 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_05ae7eda6f14 (Metraipolis archive dc_05ae7eda6f14, sha256 91c6e58de5bb4c5d1ceddec497f2248a750dcc8c0bdfdd64d552655711c3ce20)
BibTeX
@misc{dc05ae7eda6f14,
  title = {CFD Correction of Open Tip Clearance Flow in a Compressor Cascade Using VAE Latent Space Adaptation — arXiv:2609.28558},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.28558},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_05ae7eda6f14; sha256 91c6e58de5bb4c5d1ceddec497f2248a750dcc8c0bdfdd64d552655711c3ce20},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.28558. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

CFD predictions of open tip clearance flow in compressor cascades are subject to discrepancies relative to experiments, while experimental observations are sparse and high-resolution experimental ground truth is unavailable. This study proposes a non-intrusive correction method based on a variational autoencoder (VAE) and latent-space adaptation. A VAE is first trained using a dataset of 166 parametrically sampled CFD total pressure loss fields to learn a low-dimensional statistical representation of these fields. The VAE is then frozen, and a low-rank latent-space adapter is trained using only 12 paired CFD--experiment operating conditions. An observation operator maps the corrected high-resolution fields to the experimental observation space, allowing supervision to be applied only at the available measurement locations and within the measured pitchwise windows. In the current 12-fold cross-validation, the mean absolute error decreases from 0.1335 to 0.0473, the root mean square error from 0.1717 to 0.0621, and the relative $L_2$ error from 0.5108 to 0.1871. These results indicate that the method improves agreement between CFD predictions and sparse experimental observations of open tip clearance flow without modifying the RANS solver or constructing artificial high-resolution experimental labels.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-25 in cs.LG).
Categorie arXiv: Machine Learning (cs.LG).
Pagina del lavoro: https://arxiv.org/abs/2609.28558 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-08T04:50:39.173Z dalla pagina https://arxiv.org/catchup/cs.LG/2026-09-25?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).