Metraipolis › archive › dc_04d13e610118
A Guideline-Grounded Multi-Agent Framework for Personalized Exercise Prescription from Clinical and Wearable Data — arXiv:2611.03983
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2611.03983
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-04T11:50:11.778Z
- SHA-256 of the archived text
fd87290ead06f69e583317a480d273590ece0659aadb3e5d12d048c3f94a5dc0- Stable URL of this page
https://metraipolis.com/documento/dc_04d13e610118
How to cite
A Guideline-Grounded Multi-Agent Framework for Personalized Exercise Prescription from Clinical and Wearable Data — arXiv:2611.03983 — arXiv (en), https://arxiv.org/abs/2611.03983 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_04d13e610118 (Metraipolis archive dc_04d13e610118, sha256 fd87290ead06f69e583317a480d273590ece0659aadb3e5d12d048c3f94a5dc0)
BibTeX
@misc{dc04d13e610118,
title = {A Guideline-Grounded Multi-Agent Framework for Personalized Exercise Prescription from Clinical and Wearable Data — arXiv:2611.03983},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2611.03983},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_04d13e610118; sha256 fd87290ead06f69e583317a480d273590ece0659aadb3e5d12d048c3f94a5dc0},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.03983. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Translating population-level exercise guidance into individualized prescriptions requires integrating clinical and wearable data, including diagnoses, medications, functional limitations, and baseline activity, with condition-specific recommendations, a process difficult to scale beyond specialist rehabilitation settings. We developed FITTER, a multi-agent framework that integrates these data with condition-specific guidance to generate personalized FITT-VP prescriptions and applies deterministic safety audit and repair to correct rule-checkable violations. We evaluated FITTER using data from 400 All of Us participants (300 cancer, 100 stroke) against five LLM comparators through computational evaluation, ablation, and structured clinician review. FITTER achieved 98.5% safety-constraint compliance versus 75.8-85.8% for comparators and showed greater quantitative dosing precision and guideline alignment. Cancer-cohort ablation identified safety audit and repair as the largest contributor to safety-constraint compliance. Clinicians reviewed 80 prescriptions across safety, personalization, instruction concreteness, anticipated effectiveness, and clinical acceptability. FITTER provides a clinician-facing approach integrating clinical and wearable data, guidance, and explicit safety constraints. Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.MA, nuovi lavori del giorno). Categorie arXiv: Artificial Intelligence (cs.AI) ; Multiagent Systems (cs.MA). Pagina del lavoro: https://arxiv.org/abs/2611.03983 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-04T11:50:11.430Z dalla pagina https://arxiv.org/list/cs.MA/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).