Metraipolis › archive › dc_03f2df7238ca
Improvised Long Test Lengths via Stitching Scale Bar Method: Interim Testing of Laser Trackers — Europe PMC PMID:39309136
- Source
- Europe PMC (en)
- Original
- https://europepmc.org/article/MED/39309136
- DOI
- 10.6028/jres.125.016
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-08T15:22:52.364Z
- SHA-256 of the archived text
2a29f3fdae0c2549b2757c60f48acfda4af60a8f054dd6ffdad86137b0691cd3- Stable URL of this page
https://metraipolis.com/documento/dc_03f2df7238ca
How to cite
Improvised Long Test Lengths via Stitching Scale Bar Method: Interim Testing of Laser Trackers — Europe PMC PMID:39309136 — Europe PMC (en), https://europepmc.org/article/MED/39309136 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_03f2df7238ca (Metraipolis archive dc_03f2df7238ca, sha256 2a29f3fdae0c2549b2757c60f48acfda4af60a8f054dd6ffdad86137b0691cd3)
BibTeX
@misc{dc03f2df7238ca,
title = {Improvised Long Test Lengths via Stitching Scale Bar Method: Interim Testing of Laser Trackers — Europe PMC PMID:39309136},
howpublished = {Europe PMC (en)},
url = {https://europepmc.org/article/MED/39309136},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_03f2df7238ca; sha256 2a29f3fdae0c2549b2757c60f48acfda4af60a8f054dd6ffdad86137b0691cd3},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: Europe PMC (en), https://europepmc.org/article/MED/39309136. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Performance verifications of laser tracker systems (LTSs) often rely on calibrated length artifacts that are 2.3 m in length or more, as specified in International Standards Organization (ISO) and American Society of Mechanical Engineers (ASME) standards. The 2.3 m length is chosen as the minimum length that will sufficiently expose inaccuracy in LTSs. Embodiment of these artifacts often comes in the form of scale bars, fixed monuments, or a laser rail. In National Institute of Standards and Technology (NIST) Internal Report (IR) 8016, which was published in 2014 and discusses interim testing of LTSs, it was shown that a scale bar with three nests spaced 1.15 m apart was sufficient for exposing errors in LTSs. In that case, the LTS was placed symmetrically with respect to the scale bar so that both a 2.3 m symmetrical length and a 1.15 m asymmetrical length were presented to the LTS. This paper will evaluate whether a scale bar that is only 1.15 m in length can sufficiently expose errors within the LTS when it is stitched together to create a 2.3 m long test length. Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (retro-catalogo: tutto il sottoinsieme open access di Europe PMC con licenza libera). Pubblicazione: Journal of research of the National Institute of Standards and Technology, 2020 (prima pubblicazione 2020-05-28). Identificativi: PMID 39309136 · PMCID PMC11374359 · DOI 10.6028/jres.125.016. Parole chiave degli autori: Laser Scanners; Scale Bar; Interim Testing; Laser Tracker Systems. Pagina: https://europepmc.org/article/MED/39309136 — https://doi.org/10.6028/jres.125.016. Autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza dell'articolo dichiarata da Europe PMC: CC0 (la versione è indicata dall'editore sulla pagina). Abstract riportato senza modifiche al contenuto, con attribuzione; deposito marcato CC0. Letto il 2026-11-08T15:16:50.942Z tramite l'API REST ufficiale di Europe PMC (EMBL-EBI), nel rispetto del robots.txt e del crawl-delay.