Metraipolis › archive › dc_03cdbfe531de
PACE-ECG: Patient-Aware Contrastive ECG Pretraining; Leveraging Longitudinal Structure for Transferable Representations — arXiv:2611.12307
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2611.12307
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-10T18:41:50.011Z
- SHA-256 of the archived text
bd760c5bc4efbe8c6963d95b9fa169ccca556e6881922c92db5d799ee8ceb908- Stable URL of this page
https://metraipolis.com/documento/dc_03cdbfe531de
How to cite
PACE-ECG: Patient-Aware Contrastive ECG Pretraining; Leveraging Longitudinal Structure for Transferable Representations — arXiv:2611.12307 — arXiv (en), https://arxiv.org/abs/2611.12307 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_03cdbfe531de (Metraipolis archive dc_03cdbfe531de, sha256 bd760c5bc4efbe8c6963d95b9fa169ccca556e6881922c92db5d799ee8ceb908)
BibTeX
@misc{dc03cdbfe531de,
title = {PACE-ECG: Patient-Aware Contrastive ECG Pretraining; Leveraging Longitudinal Structure for Transferable Representations — arXiv:2611.12307},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2611.12307},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_03cdbfe531de; sha256 bd760c5bc4efbe8c6963d95b9fa169ccca556e6881922c92db5d799ee8ceb908},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.12307. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Foundation models for physiological signals are commonly evaluated on in-domain interpretation tasks, but their ability to transfer to longitudinal clinical prognosis across healthcare systems remains uncertain. We developed PACE-ECG, an ECG pretraining framework that combines contrastive learning across temporally neighbouring recordings from the same patient with clinically guided multitask supervision. We evaluated frozen ECG representations for post-myocardial-infarction all-cause mortality and incident heart failure prediction across MIMIC-IV and two external HEEDB cohorts, comparing the proposed representation with DeepECG-SSL, a state-of-the-art model, and two control baselines. Across both downstream tasks, the proposed model outperformed DeepECG-SSL in-domain (AUROC +1.9% for mortality and +4.0% for heart failure) and on external populations in HEEDB-Boston (+5.6% for mortality +10.3% for heart failure) and HEEDB-Atlanta (+6.9% for mortality +11.0% for heart failure) while using an encoder 41 times smaller and a fraction of the pretraining data. A matched ablation showed that patient-temporal pairing improved external mortality and heart failure AUROC over generic self-supervision by 7.0% and 9.4% on HEEDB-Boston and 8.9% and 9.3% on HEEDB-Atlanta. These findings indicate that pretraining-objective design greatly influences downstream transfer alongside model and data scale, and that in-domain performance alone is insufficient to establish the clinical generalisability of ECG foundation representations. Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.AI, nuovi lavori del giorno). Categorie arXiv: Artificial Intelligence (cs.AI). Pagina del lavoro: https://arxiv.org/abs/2611.12307 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-10T18:37:37.546Z dalla pagina https://arxiv.org/list/cs.AI/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).