Metraipolis › archive › dc_02f82559477b

DBCM: Dual-Branch Calibration Module for Test-Time Adaptation in Time Series Forecasting — arXiv:2610.32071

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.32071
License (as archived)
CC0-1.0
Archived
2026-10-26T20:11:46.833Z
SHA-256 of the archived text
2c63681ff4b30cdf4fcb6bc228e6d2729e7c78a4d7977a33360c78d060e82423
Stable URL of this page
https://metraipolis.com/documento/dc_02f82559477b

How to cite

DBCM: Dual-Branch Calibration Module for Test-Time Adaptation in Time Series Forecasting — arXiv:2610.32071 — arXiv (en), https://arxiv.org/abs/2610.32071 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_02f82559477b (Metraipolis archive dc_02f82559477b, sha256 2c63681ff4b30cdf4fcb6bc228e6d2729e7c78a4d7977a33360c78d060e82423)
BibTeX
@misc{dc02f82559477b,
  title = {DBCM: Dual-Branch Calibration Module for Test-Time Adaptation in Time Series Forecasting — arXiv:2610.32071},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.32071},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_02f82559477b; sha256 2c63681ff4b30cdf4fcb6bc228e6d2729e7c78a4d7977a33360c78d060e82423},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.32071. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Non-stationarity induces test-time distribution shifts in time series forecasting (TSF), resulting in forecast residuals between predictions and the corresponding ground truth. Recent works on test-time adaptation for TSF address this by introducing lightweight calibration modules around frozen forecasters, updated using observations that become incrementally available at test time. Existing approaches typically employ channel-wise adapters, implicitly assuming that forecast residuals are inherently channel-specific. However, we observe that forecast residuals often exhibit substantial shared structure across channels, suggesting that fully independent channel-wise parameterization may be redundant. Motivated by this observation, we propose the Dual-Branch Calibration Module (DBCM), which shares adaptation capacity across channels through a shared adapter while retaining limited channel-specific flexibility through a low-rank channel-wise adapter, further enhanced by channel mixing and nonlinear gated modulation. Extensive experiments show that DBCM consistently outperforms prior methods across diverse datasets, horizons, and backbones.

Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.LG, nuovi lavori del giorno).
Categorie arXiv: Machine Learning (cs.LG) ; Machine Learning (stat.ML).
Pagina del lavoro: https://arxiv.org/abs/2610.32071 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-26T19:49:03.382Z dalla pagina https://arxiv.org/list/cs.LG/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).