Metraipolis › archive › dc_02bec9f80054
A Standardized Framework for Machine Learning in Power System Protection — arXiv:2608.20181
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.20181
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-18T11:48:26.988Z
- SHA-256 of the archived text
5c940b77fa6b0f4e7d05add5854395d759d29d1d92f0231075325298c331041c- Stable URL of this page
https://metraipolis.com/documento/dc_02bec9f80054
How to cite
A Standardized Framework for Machine Learning in Power System Protection — arXiv:2608.20181 — arXiv (en), https://arxiv.org/abs/2608.20181 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_02bec9f80054 (Metraipolis archive dc_02bec9f80054, sha256 5c940b77fa6b0f4e7d05add5854395d759d29d1d92f0231075325298c331041c)
BibTeX
@misc{dc02bec9f80054,
title = {A Standardized Framework for Machine Learning in Power System Protection — arXiv:2608.20181},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.20181},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_02bec9f80054; sha256 5c940b77fa6b0f4e7d05add5854395d759d29d1d92f0231075325298c331041c},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.20181. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Studies of machine-learning-based power-system protection increasingly report near-perfect scores, yet the meaning of those scores depends strongly on the evaluation setting. Protection task, physical scope, measurements, timing, targets, preprocessing, and validation often vary jointly and remain incompletely specified. This paper proposes a standardization-oriented framework that treats evaluation design as part of the scientific contribution. It defines seven required study dimensions: protection objective, physical scope, observability, timing and decision windows, targets and sample validity, validation protocol, and evaluation outputs. The framework is instantiated in a bounded case study on the public PROTECT-90 electromagnetic-transient benchmark, comprising 9022 simulated episodes from a 90 kV double-line topology, for onset-conditioned fault classification and localization. Under centralized sensing, simulation-metadata-aligned 20 ms windows, and episode-grouped validation, a multi-layer perceptron (MLP) achieved a five-fold mean macro-averaged F1 score of 0.991 +/- 0.001 for classification and a localization mean absolute error of 10.20 +/- 0.25% of line length (mean +/- std across episode-grouped folds). Extending the decision horizon to 50 ms preserved this task-dependent performance asymmetry, while reduced observability approximately doubled the MLP localization error but had little effect on classification. A synchronized two-ended conventional locator outperformed the learning locators under its richer clean information set, and measurement degradation showed that clean predictive performance did not determine robustness. The framework turns evaluation assumptions into explicit, reproducible evidence and provides a basis for more comparable, auditable evaluation and future certification-oriented assessment of machine-learning protection functions. Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-08-21 in cs.LG). Categorie arXiv: Machine Learning (cs.LG) ; Artificial Intelligence (cs.AI); Signal Processing (eess.SP). Pagina del lavoro: https://arxiv.org/abs/2608.20181 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-18T11:47:43.340Z dalla pagina https://arxiv.org/catchup/cs.LG/2026-08-21?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).